仪器简介:
XP系列大量程天平采用高速单模块称量传感器(MonoBlocHighSpeed),以**快速度传递准确称量结果,具有良好的抗冲击、抗过载性能。
全自动校准技术(ProFACT)——温度漂移触发的自动内部校准,确保称量结果的准确性。
彩色触摸显示屏(Smart Screen),方便天平称量菜单和参数设置。
具有状态显示的外置红外感应器选件(ErgoSens),实现天平无需用手接触的操作。
内置RS232通讯接口和灵活的6种通讯接口选件(RS232、LocalCan、BTS、PS/2、Ethernet和MiniMettler),方便连接打印和电脑等外围设备。
优化天平适应性的称量参数设置,满足不同称量环境要求。
具有简单称量、统计称量、公式称量、计件称量、百分比称量、密度测定以及优化的动态称量等内置应用程序。
通过E-Loader软件,实现天平软件的即时更新。
技术指标
**大称量值 16100g
可读性 0.1g
**大称量值的重复性(sd) 0.08g
线性误差 0.2g
典型稳定时间 1.5s
秤盘尺寸(mm) 280×360
天平外形尺寸(W×D×H) [mm] 280×505×130
Balance model |
XP8001 L |
XP16001 L |
XP32001 L |
XP32001L DR |
XP64001 L |
XP16000 L |
XP32000 L |
XP64000 L |
Maximum capacity |
8.1 kg |
16.1 kg |
32.1 kg |
32.1 kg |
64.1 kg |
16.1 kg |
32.1 kg |
64.1 kg |
Maximum capacity, fine range |
– |
– |
– |
6.4 kg |
– |
– |
– |
– |
Readability |
0.1 g |
0.1 g |
0.1 g |
1 g |
0.1 g |
1 g |
1 g |
1 g |
Readability, fine range |
– |
– |
– |
0.1 g |
– |
– |
– |
– |
Repeatability (sd) |
0.08 g |
0.08 g |
0.08 g |
0.6 g |
0.1 g |
0.6 g |
0.6 g |
0.6 g |
Repeatability, fine range (sd) |
– |
– |
– |
0.1 g |
– |
– |
– |
– |
Linearity |
0.2 g |
0.2 g |
0.3 g |
0.3 g |
0.5 g |
0.6 g |
0.6 g |
0.6 g |
Eccentric load deviation (test load) |
0.3 g (5 kg) |
0.3 g (5 kg) |
0.3 g (10 kg) |
1 g (10 kg) |
0.5 g (20 kg) |
1 g (5 kg) |
1 g (10 kg) |
1 g (20 kg) |
Settling time |
1.5 s |
1.5 s |
1.5 s |
1.5 s |
1.8 s |
1.2 s |
1.2 s |
1.5 s |
Platform dimensions (WxD x H ) |
360x280x130mm
|
|||||||
Terminal dimensions (WxD ) |
194x145mm |
|||||||
Weighing pan dimensions (WxD ) |
280x360mm |
Balance model |
XS8001L |
XS16001L |
XS32001L |
XS32001LDR |
XS16000L |
XS32000L |
Limit values |
|
|||||
Maximum capacity; fine range |
8.1 kg; — |
16.1 kg; — |
32.1 kg; — |
32.1 kg; 6.4 kg |
16.1 kg; — |
32.1 kg; — |
Readability; fine range |
0.1 g; — |
0.1 g; — |
0.1 g; — |
1 g; 0.1 g |
1 g; — |
1 g; — |
Repeatability; fine range1)2) |
0.08 g; — |
0.08 g; — |
0.08 g; — |
0.6 g; 0.1 g |
0.6 g; — |
0.6 g; — |
Linearity deviation |
0.2 g |
0.2 g |
0.3 g |
0.3 g |
0.6 g |
0.6 g |
Sensitivity offset (test load)3) |
0.64 g (8 kg) |
0.8 g (16 kg) |
0.96 g (32 kg) |
0.96 g (32 kg) |
1.28 g (16 kg) |
1.92 g (32 kg) |
Balance dimensions4) |
360 x 404 x 130 |
|||||
Weighing pan dimensions5) |
360 x 280 |
|||||
Typical values |
|
|||||
Repeatability; fine range2) |
0.04 g; — |
0.04 g; — |
0.04 g; — |
0.4 g; 0.04 g |
0.4 g; — |
0.4 g; — |
Minim. weight/USP; fine range |
120 g; — |
120 g; — |
120 g; — |
1200 g; 120 g |
1200 g; — |
1200 g; — |
Minimum weight6); fine range |
8 g; — |
8 g; — |
8 g; — |
80 g; 8 g |
80 g; — |
80 g; — |
Settling time |
1.5 s |
1.5 s |
1.5 s |
1.5 s |
1.2 s |
1.2 s |
Linearity deviation |
0.13 g |
0.13 g |
0.2 g |
0.2 g |
0.4 g |
0.4 g |
Sensitivity offset (test load)3) |
0.19 g (8 kg) |
0.26 g (16 kg) |
0.32 g (32 kg) |
0.32 g (32 kg) |
0.38 g (16 kg) |
0.65 g (32 kg) |